Body Style: Multipole-Single Actuator Type Bushing Length: 0.250 Inches Nominal Body Length: 1.840 Inches Maximum Body Width: 0.730 Inches Minimum And 0.770 Inches Maximum Body Height: 1.030 Inches Maximum Case Material: Plastic Center To Center Distance Between Terminals Parallel To Length: 0.673 Inches Minimum And 0.735 Inches Maximum Center To Center Distance Between Terminals Parallel To Width: 0.593 Inches Minimum And 0.655 Inches Maximum End Item Identification: Used On C130-J Hercules Aircraft Pole Quantity: 3 Mounting Facility Type And Quantity: 1 Threaded Bushing Thread Quantity Per Inch: 32 Maximum Continuous Load Current Rating Per Pole: 20.0 Amperes Ac All Locations Operating Voltage Type And Rating Per Pole In Volts: 120.0 Ac All Locations Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps: 2000.0 Ac All Locations Circuit Protection Type: Overcurrent All Locations Trip Release Method: Thermal All Locations Trip Release Characteristic: Time Delay All Locations Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent: 138.0 All Locations Reset Method: Manual Main Contact Tripping Mechanism Type: Trip Free Manual Actuator Type And Quantity: 1 Push-Pull Actuator Function: Trip-Reset Actuator Position Designation: Between Pole One And Two Internal Trip Release Configuration: Series Trip All Locations Nominal Thread Size: 0.4688 Inches Trip Delay Time In Seconds Per Rated Continuous Current: 5.000 Minimum At 200 Pct All Locations And 20.000 Maximum At 200 Pct All Locations Trip Release Ambient Temp Rating: 25.0 Deg Celsius Nominal All Locations Frequency In Hertz: 400.0 All Locations Thread Series Designator: Uns Terminal Type And Quantity: 6 Screw