Please note: International orders are shipped from their respective locations, which may take an additional 7-10 days to process. We strive to consolidate items into one shipment to minimize duties and taxes. However, if items are located in different locations, separate shipments may be necessary.
Klixon 7277 series is designed for applications that do not require the tighter performance characteristics and approvals of our military circuit breakers.
Originally developed as an alternative to slow blow fuses, the trip–free 7277 is used extensively as primary electrical circuit protection on general aviation aircraft.
The military grade version of this circuit breaker is the Klixon 7274-2 series. The 7277 and 7274-2 series circuit breakers are physically and electrically identical, with the exception that the 7277 has wider calibration limits.
Performance Data
Interrupt Current
0.50–5 amps: unlimited at 28 VDC 7.50–15 amps: 2,000 amps at 28 VDC 0.50–1.50 amps: unlimited at 120 VAC, 400 Hz 2–5 amps: 800 amps at 120 VAC, 400 Hz 7.50–20 amps: 500 amps at 120 VAC, 400 Hz